11.3 HPA-O10Premium | HPA-O10CPremium |
HPA-O13Premium | HPA-O13CPremium
Connect the cables according to the following diagram.
X5 / DHC X3 / WP X4 / Steuerung
L2 L3L1 N L2 L3L1 N
L
ON
-
ERR
N
2,6 kW L1 N PE
3,0 kW L2 N PE
3,2 kW L3 N PE
5,6 kW L1 L2 N PE
5,8 kW L1 L3 N PE
6,2 kW L2 L3 N PE
8,8 kW L1 L2 L3 N PE
3/N/PE~400/50
C 16A
1/N/PE~230/50
C 16A
3/N/PE~400/50
C 16A
BUS
X2
L
H
T
„+“
26_03_01_1859
1
1 Earth terminal for screening the LV lead
X2 
BUS High H
BUS Low L
BUS earth
BUS "+" (is not connected)
X3 
L1, L2, L3, N, PE
X4 
-
ON
ERR
Power supply: L, N, PE
X5 
L1, L2, L3, N, PE
 
2.6kW L1 PE
3.0kW L2 PE
3.2kW L3 PE
5.6kW L1 L2 PE
5.8kW L1 L3 PE
6.2kW L2 L3 PE
8.8kW L1 L2 L3 PE
Earth the LV lead by inverting the screen over the cable
sheath and clamping it under the earth terminal.
Then check that the strain relief fittings are working as
intended.
11.4 HPA-O13SPremium | HPA-O13CSPremium
Connect the cables according to the following diagram.
BUS
X2
L
H
T
„+“
X5 / DHC X3 / WP X4 / Steuerung
N LL N L N
L
ON
-
ERR
N
3,0 kW L N PE
3,2 kW L N PE
6,2 kW L N L N PE
1/N/PE~230/50
C 32A
1/N/PE~230/50
C 16A
1/N/PE~230/50
C 20A
D0000037825
1
1 Earth terminal for screening the LV lead
X2 
BUS High H
BUS Low L
BUS earth
BUS "+" (is not connected)
X3 
L, N, PE
X4 
-
ON
ERR
Power supply: L, N, PE
X5 
L, N, L, N, PE
 
3.0kW L N PE
3.2kW L N PE
6.2kW L N L N PE
Earth the LV lead by inverting the screen over the cable
sheath and clamping it under the earth terminal.
Then check that the strain relief fittings are working as
intended.