24 | 
16.1 Checking the IWS DIP switch settings
Carry out the following steps to make the IWS accessible.
26_03_01_1866
Remove the cover.
26_03_01_1869
Remove the bracket highlighted in grey.
D0000075152
1
1 IWS
Lift the control panel.
Turn the control panel around.
IWS
BA
BA
26_03_01_0921
1
2
3
4
1 LEDs
2 DIP switch (WP-Typ)
3 Reset button
4 DIP switch (BA)
DIP switch (WP-Typ)
The DIP switch (WP-Typ) on the IWS serves to set the relevant
heat pump type.
Factory setting
Compressor mode with electric emergency/booster heater
WP - Typ
ON
1 2 3 4
D0000057054
Check whether the DIP switch is set correctly.
Compressor mode with an external second heat generator
!
Material losses
In this case, do not connect the electric emergency/boost-
er heater.
If the appliance is operated in dual mode operation with an ex-
ternal second heat generator or as a module with a further heat
pump, set the DIP switch as shown.
WP - Typ
ON
1 2 3 4
D0000057055

Table of Contents

Related product manuals