| 41
17.5 Data table
The performance data apply for new appliances with clean heat exchangers.
The power consumption figures for the integral auxiliary drives are maximum values and may vary subject to operating point.
The power consumption of the integral auxiliary drives is included in the output details of the heat pump (to EN 14511).
HPA-O 7
-
HPA-O 7
-
HPA-O 10
HPA-O 10
-
HPA-O 13
-
HPA-O 13
-
HPA-O 13
HPA-O 13
-
238976 238977 238978 238979 238980 238981 238982 238983
Heating output
Heating output at A7/W35 (min./max.) kW 3.50/7.40 3.50/7.40 7.85/10.80 7.85/10.80 7.85/12.85 7.85/12.85 7.85/12.85 7.85/12.85
Heating output at A2/W35 (min./max.) kW 3.10/7.09 3.10/7.09 8.33/10.71 8.33/10.71 8.33/13.64 8.33/13.64 8.33/13.64 8.33/13.64
Heating output at A-7/W35 (min./max.) kW 2.50/6.86 2.50/6.86 6.16/10.14 6.16/10.14 6.16/12.86 6.16/12.86 6.16/12.86 6.16/12.86
Heating output at A7/W65 (EN14511) kW 4.56 4.56 8.45 8.45 8.45 8.45 8.45 8.45
Heating output at A7/W35 (EN14511) kW 4.68 4.68 7.84 7.84 8.00 8.00 7.84 7.84
Heating output at A2/W35 (EN 14511) kW 4.23 4.23 8.33 8.33 8.33 8.33 8.33 8.33
Heating output at A-7/W35 (EN 14511) kW 6.86 6.86 9.54 9.54 12.86 12.86 12.86 12.86
Heating output at A-7/W55 (EN 14511) kW 7.09 7.09 10.73 10.73 13.97 13.97 13.93 13.93
Heating output at A-7/W65 (EN 14511) kW 7.30 7.30 11.06 11.06 14.30 14.30 14.30 14.30
Heating output at A-15/W35 (EN 14511) kW 6.16 6.16 8.51 8.51 11.96 11.96 12.05 12.05
Heating output in silent mode at A-7/W35 (70 %) kW 4.80 4.80 7.10 7.10 9.00 9.00 9.00 9.00
Max. heating output in silent mode at A-7/W35 kW 4.30 4.30 7.10 7.10 7.85 7.85 7.85 7.85
Max. cooling capacity at A35/W7 kW 7.86 11.49 14.88 14.88
Cooling capacity at A35/W7 partial load kW 2.15 4.80 4.80 4.80
Max. cooling capacity at A35/W18 kW 8.66 15.26 17.06 17.06
Cooling capacity at A35/W18 partial load kW 3.25 6.76 6.76 6.76
Power consumption
Power consumption at A7/W65 (EN 14511) kW 1.93 1.93 3.28 3.28 3.28 3.28 3.28 3.28
Power consumption at A7/W35 (EN14511) kW 1.11 1.11 1.54 1.54 1.66 1.66 1.54 1.54
Power consumption at A2/W35 (EN 14511) kW 1.09 1.09 2.01 2.01 2.01 2.01 2.01 2.01
Power consumption at A-7/W35 (EN 14511) kW 2.42 2.42 2.93 2.93 4.31 4.31 4.16 4.16
Power consumption at A-7/W55 (EN 14511) kW 3.38 3.38 4.10 4.10 5.94 5.94 5.76 5.76
Power consumption at A-7/W65 (EN 14511) kW 3.95 3.95 5.25 5.25 7.53 7.53 7.53 7.53
Power consumption at A-15/W35 (EN 14511) kW 2.45 2.45 2.91 2.91 4.56 4.56 4.48 4.48
Max. power consumption, fan heating kW 0.10 0.10 0.20 0.20 0.20 0.20 0.20 0.20
Power consumption, emergency/booster heater kW 6.20 6.20 8.80 8.80 8.80 8.80 8.80 8.80
Coefficient of performance
COP at A7/W65 (EN 14511) 2.36 2.36 2.57 2.57 2.57 2.57 2.57 2.57
COP at A7/W35 (EN14511) 4.23 4.23 5.09 5.09 4.82 4.82 5.09 5.09
COP at A2/W35 (EN 14511) 3.88 3.88 4.14 4.14 4.14 4.14 4.14 4.14
COP at A-7/W35 (EN 14511) 2.83 2.83 3.26 3.26 2.98 2.98 2.93 2.93
COP at A-7/W55 (EN 14511) 2.10 2.10 2.62 2.62 2.35 2.35 2.42 2.42
COP at A-7/W65 (EN 14511) 1.85 1.85 2.10 2.10 1.90 1.90 1.90 1.90
COP at A-15/W35 (EN 14511) 2.51 2.51 2.92 2.92 2.62 2.62 2.69 2.69
SCOP (EN 14825) 3.84 4.04 4.70 4.87 4.39 4.53 4.63 4.76
Max. cooling capacity factor at A35/W7 2.41 2.53 2.38 2.38
Cooling capacity factor at A35/W7 partial load 2.39 2.84 2.84 2.84
Max. cooling capacity factor at A35/W18 2.87 3.12 2.83 2.83
Cooling capacity factor at A35/W18 partial load 3.78 3.76 3.76 3.76
Sound emissions
Sound power level (EN 12102) dB(A) 50 50 54 54 54 54 54 54
Sound pressure level at 5m in free field dB(A) 28 28 32 32 32 32 32 32
Max. sound power level for outdoor installation dB(A) 61 61 66 66 66 66 66 66
Sound power level in silent mode 70 % dB(A) 52 52 54 54 57 57 57 57
Max. sound power level, silent mode dB(A) 50 50 54 54 54 54 54 54
Application limits
Min. application limit, heat source °C -20 -20 -20 -20 -20 -20 -20 -20
Max. application limit, heat source °C 40 40 40 40 40 40 40 40
Min. application limit on the heating side °C 15 15 15 15 15 15 15 15
Max. application limit on the heating side °C 65 65 65 65 65 65 65 65
Application limit, heat source at W65 °C -20 -20 -20 -20 -20 -20 -20 -20
Min. cooling mode application limit for outside temperature °C 15 15 15 15
Max. cooling mode application limit for outside temperature °C 40 40 40 40