Repair instructions
HPG-I 04-06-08-12-15 S-CS-DS-DCS
Premium
10.5
Legend refrigerant circuit
Pressure sensor high pressure
Pressure sensor low pressure
Pressure switch high pressure
Pressure sensor heating circuit
Pressure sensor Heat source
Pressure switch heat source (On = 1.0 bar / Off = 0.5 bar)
Temperature sensor WP flow
Temperature sensor WP return
Temperature sensor hot water tank
Temperature sensor heating flow MFG
Temperature sensor heat source flow
Temperature sensor heat source return
Temperature sensor condenser outlet
Temperature sensor evaporator outlet
Temperature sensor compressor inlet
Oil sump temperature sensor
Temperature sensor hot gas
Temperature sensor compressor housing
Safety temperature limiter (STB)
Emergency/auxiliary heater (E1)
Flow rate WP flow heating
Stepper motor Expansion valve
Motor changeover valve (heating / cooling)
Motor switch valve (hot water / heating)
Circulating pump Heat source