ENGLISH
www.stiebel-eltron.com SH S | 25
INSTALLATION
Specication
16.3 Heat-up diagram
The heat-up time depends on the cylinder capacity, cold water
inlet temperature and heating output.
Diagram with 15°C cold water temperature:
Set temperature setting 82°C
10080 15030
2
4
6
2
4
5
8
10
12
14
50 120
1
3
84�02�02�0041�
X Nominal capacity [I]
Y Duration [h]
1 1kW
2 2kW
3 3kW
4 4kW
5 6kW
16.4 Fault conditions
In the event of a fault, temperatures of up to 95°C at 0.6MPa
can occur.
16.5 Details on energy consumption
Product datasheet: Conventional water heaters to regulation (EU) no. 812/2013 and 814/2013
SH 30 S SH 50 S SH 80 S SH 100 S SH 120 S SH 150 S
073047 073048 073049 073050 073051 073052
Manufacturer STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
Load profile S M M L L XL
Energy efficiency class B C C C C C
Energy conversion efficiency % 36 38 37 38 38 39
Annual power consumption kWh 518 1349 1381 2666 2705 4321
Default temperature setting °C 60 60 60 60 60 60
Sound power level dB(A) 15 15 15 15 15 15
Option for exclusive operation during
off-peak periods
- - - - - -
Smart function - - - - - -
Daily power consumption kWh 2.437 6.233 6.419 12.288 12.516 19.859
Amount of mixed water 40 °C l 50 80 122 133 182 229