2.2 Electrical connection
WARNING!
ESD damage!
Electrostatic discharge can lead to
damage to electronic components!
Î Take care to discharge
properly before touching the
inside of the device! To do
so, touch a grounded surface
such as a radiator or tap!
Note:
The pump speed must be set to 100 %
when auxiliary relays or valves are connec-
ted.
input for analog
Grundfos Direct
Sensors™
input for digital
Grundfos Direct Sensors™
potential-free
changeover relay
sensor
ground common terminal block
sensor terminals
protective earth
conductor common
terminal block (PE)
neutral conductor
common terminal
block
Note
For more details about the initial commissi-
oning procedure, see page 12.
Note
Connecting the device to the power supply
must always be the last step of the instal-
lation!
The controller is equipped with 14 relays in total to
which loads such as pumps, valves, etc. can be con-
nected:
Relays 1 ... 13 are semiconductor relays, designed for
pump speed control:
Conductor R1 ... R13
Neutral conductor N (common terminal block)
Protective earth conductor
(common terminal
block)
Relay 14 is a potential-free changeover relay:
R14-A = normally open contact
R14-M = centre contact
R14-R = normally closed contact
WARNING!
Electric shock!
Upon opening the housing, live
parts are exposed.
Î Always disconnect the
controller from power supply
before opening the housing!
Depending on the product version, mains cables
and sensor cables are already connected to the de-
vice. If that is not the case, please proceed as follows:
Temperature sensors have to be connected to the
terminals S1 ... S12 and GND (either polarity).
PWM (0-10 V)
terminals
VBus
®