www.stiebel-eltron.com UFP 5 h | 17
ENGLISH
INSTALLATION
Settings
10.1.1 Appliance handover
Explain the functions of the appliance to the user. Show the
user how to operate the appliance.
Make the user aware of potential dangers, especially the risk
of scalding.
Hand over these instructions and, if applicable, the instruc-
tions for any accessories.
10.2 Recommissioning
See chapter "Installation/ Commissioning/ Initial start-up".
11. Settings
11.1 Setting the temperature limit
D0000052049
1
2
1 Temperature selector
2 Limiting ring
Placing the limiting ring behind the temperature selector allows
you to limit the setting range of the temperature selector. The
appliance temperature can be limited to either a maximum or
minimum temperature.
The limiting ring has four holes and two end-stops around its
edge. The holes are inscribed with temperature markings. Insert
the limiting ring into the appliance cover so that the spike in the
appliance cover pokes through one of the holes with a tempera-
ture marking. The inscription on the limiting ring must be visible
after insertion.
Setting a maximum temperature of 45°C, 55°C, 65°C
Turn the temperature selector to zero (fully anti-clockwise to
"°C").
Pull off the temperature selector and the limiting ring.
Insert the limiting ring into the appliance cover so that the
spike in the appliance cover pokes through the hole with the
required temperature marking.
Install the temperature selector set to zero (°C).
The maximum appliance temperature is limited to the temperature
indicated on the chosen hole.
Setting a minimum temperature limit >65°C
Turn the temperature selector clockwise as far as it will go
(85).
Pull off the temperature selector and the limiting ring.
Insert the limiting ring into the appliance cover so that the
spike in the appliance cover pokes through the hole with the
55 temperature marking.
Install the temperature selector set as far clockwise as possi-
ble (85).
The temperature can be set to between 65 and 85°C.
12. Shutdown
Isolate the appliance from the power supply by removing the
plug or by tripping the MCB in the fuse box.
Drain the appliance (see chapter "Installation/ Maintenance/
Draining the appliance").
13. Troubleshooting
Problem Cause Remedy
The appliance does
not supply hot
water.
The high limit
safety cut-out has
responded.
Remedy the cause of the fault. If
necessary, replace the temperature
controller. Allow the appliance to
cool down. If you have isolated the
appliance from the power supply,
the high limit safety cut-out will be
reset automatically.
Loud boiling noises
inside the appliance.
The appliance is
scaled up.
Descale the appliance.
14. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
of the appliance from the power supply.
Dismantle the appliance for maintenance work.
14.1 Draining the appliance
WARNING Burns
Hot water may escape during the draining process.
Drain the appliance via its connectors.

Table of Contents

Other manuals for STIEBEL ELTRON UFP 5 h