18 | UFP 5 h www.stiebel-eltron.com
INSTALLATION
Specication
14.2 Opening the appliance
D0000034699
Pull off the temperature selector and the limiting ring.
Remove the screws from underneath the temperature
selector.
Open the appliance cover by lowering the bolt screws in-
wards and pivot the cover upwards, then remove it.
14.3 Descaling the appliance
!
Material losses
Never treat the cylinder surface with descaling agents.
Remove the flanged immersion heater.
Carefully tap the heating element to remove large limescale
deposits.
Immerse the heating element up to the flange plate in desca-
ling agent.
14.4 Checking the earth conductor
Pull off the temperature selector and the limiting ring.
Check the earth conductor (in Germany, e.g. DGUV3) across a
temperature controller fixing screw and the earth conductor
contact of the power cable.
14.5 Replacing the power cable
The power cable must only be replaced by a qualified contractor
with an original spare part. Alternatively, the H05VV-F3x1.0 cable
may be used.
14.6 Positioning the temperature sensor in its
protective pipe
When replacing the temperature controller, guide the tem-
perature sensor into its protective pipe.
Secure the temperature sensor in place below the earthed
plug.
26�02�06�0219
200
15. Specification
15.1 Dimensions and connections
418
29
305
100
140
222
70
252
c06
i13
c01
D0000024828
UFP 5 h UFP 5 h LABS
c01 Cold water inlet Male thread G 1/2 A G 1/2 A
c06 DHW outlet Male thread G 1/2 A G 1/2 A
i13 Wall mounting bracket
15.2 Wiring diagram
1/N/PE ~ 220 - 240V
LN
85�02�06�0001