INSTALLATION
Installation
www.stiebel-eltron.com WPL ICS classic | WPL IKCS classic | 13
10.1.1 Transport using a transport aid
To facilitate transport, you can fit a transport aid to the r.h. side
panel of the appliance (see chapter "Appliance description/ Fur-
ther accessories").
Remove the r.h. side panel of the appliance (see chapter "Fit-
ting the appliance casing").
D0000073928
1
1 Transport aid
Fit the transport aid to the appliance frame using the screws
provided.
Tilt the appliance through about 45° onto its r.h. side.
Lift the appliance carefully.
Transport the appliance to the installation location.
10.2 Siting
Note
There are fixing screws at the bottom of the appliance
frame to secure the front and side panels.
When siting the appliance, observe the air discharge
direction.
Position the appliance on the prepared substrate.
D0000078840
Push the sliding blocks supplied under the adjustable feet,
so the appliance can be moved more easily to the required
position.
Observe minimum clearances (see chapter "Preparations/
Minimum clearances").
Level the appliance vertically by turning the height-adjusta-
ble feet.
10.3 Flow and return connection
!
Material losses
In cooling mode, condensate can form when the dew
point temperature is undershot.
Take suitable measures to prevent the formation of
condensate.
D0000069079
27
6
5
4
3
1
1 Manual air vent valve
2 "Safety valve drain" connection
3 "Heat exchanger flow" connection
4 "Heat exchanger return" connection
5 "Heating return" connection
6 "Heating flow" connection
7 Condensate drain outlet
If only one return connection is used, seal off the one that is
unused.
Cooling with a buffer cylinder
Install an immersion/contact sensor in the heating flow,
downstream of the buffer cylinder.
10.4 Fitting the push-fit connectors
Note
The plastic push-fit connectors are not suitable for instal-
lation in the DHW line.
Install the push-fit connectors only in the heating
circuit.
Material losses
Tighten the screw cap of the push-fit connector by hand.
Never use a tool.
Material losses
To ensure the push-fit connector is held securely, pipes
with a surface hardness>225HV (e.g. stainless steel)
must have a groove.
Using a pipe cutter, cut a groove (depth ap-
prox.0.1mm) at a defined distance from the end of
the pipe.
- Pipe diameter 22mm: 17±0.5mm
- Pipe diameter 28mm: 27.5±0.5mm
How the push-fit connectors work
The push-fit connectors are equipped with a retainer with stain-
less steel serrations and an O-ring for sealing. The push-fit con-
nectors also have a "twist and secure" function. Simply turning
the screw cap by hand will secure the pipe in the connector and
push the O-ring against the pipe to seal it.

Table of Contents