INSTALLATION
Specication
www.stiebel-eltron.com WPL ICS classic | WPL IKCS classic | 39
19.4 Data table
The output data refers to new appliances with clean heat exchangers.
The power consumption of the integral auxiliary drives represents the maximum value and may vary subject to operating point.
The power consumption of the integral auxiliary drives is included in the output data for the appliance (to EN 14511).
WPL 09 ICS clas-
sic
WPL 09 IKCS
classic
WPL 17 ICS clas-
sic
WPL 17 IKCS
classic
236375 236377 236376 236378
Heating output
Heating output at A7/W35 (min./max.) kW 1.3/4.5 1.3/4.5 2.5/9.0 2.5/9.0
Heating output at A2/W35 (min./max.) kW 1.3/4.5 1.3/4.5 2.7/9.0 2.7/9.0
Heating output at A-7/W35 (min./max.) kW 1.3/4.2 1.3/4.2 2.9/8.0 2.9/8.0
Heating output at A10/W35 (EN 14511) kW 1.98 1.98 4.34 4.28
Heating output at A7/W35 (EN 14511) kW 2.06 2.06 4.27 4.22
Heating output at A7/W55 (EN 14511) kW 2.10 2.10 3.81 3.75
Heating output at A2/W35 (EN 14511) kW 2.64 2.62 5.02 4.95
Heating output at A2/W55 (EN 14511) kW 2.39 2.37 4.42 4.34
Heating output at A-7/W35 (EN 14511) kW 4.23 4.18 8.02 7.80
Heating output at A-7/W55 (EN 14511) kW 3.93 3.89 3.14 3.03
Heating output at A-15/W35 (EN 14511) kW 3.64 3.45 6.29 6.21
Heating output at A-20/W35 (EN 14511) kW 3.16 2.99 5.24 5.13
Cooling capacity at A35/W18 max. kW 3.00 3.00 6.00 6.00
Cooling capacity at A35/W18 partial load kW 1.85 1.85 3.60 3.60
Cooling capacity at A35/W7 max. kW 3.00 3.00 5.25 5.25
Cooling capacity at A35/W7 partial load kW 1.44 1.44 3.27 3.27
Heating output in silent mode at A-7/W35 (70 %) kW 3.12 3.12 5.14 5.14
Power consumption
Power consumption at A10/W35 (EN 14511) kW 0.40 0.40 0.83 0.85
Power consumption at A7/W35 (EN 14511) kW 0.44 0.44 0.90 0.92
Power consumption at A7/W55 (EN 14511) kW 0.80 0.80 1.48 1.49
Power consumption at A2/W35 (EN 14511) kW 0.69 0.70 1.31 1.34
Power consumption at A2/W55 (EN 14511) kW 1.03 1.04 1.94 1.96
Power consumption at A-7/W35 (EN 14511) kW 1.34 1.36 3.03 3.02
Power consumption at A-7/W55 (EN 14511) kW 1.83 1.84 1.58 1.56
Power consumption at A-15/W35 (EN 14511) kW 1.36 1.31 2.55 2.56
Power consumption at A-20/W35 (EN 14511) kW 1.26 1.27 2.25 2.26
Power consumption, emergency/booster heater kW 5,9 5,9 5,9 5,9
Coefficient of performance
COP at A10/W35 (EN 14511) 4.95 4.95 5.20 5.04
COP at A7/W35 (EN 14511) 4.68 4.68 4.74 4.60
COP at A7/W55 (EN 14511) 2.64 2.64 2.58 2.51
COP at A2/W35 (EN 14511) 3.83 3.76 3.83 3.70
COP at A2/W55 (EN 14511) 2.33 2.28 2.27 2.21
COP at A-7/W35 (EN 14511) 3.16 3.07 2.63 2.58
COP at A-7/W55 (EN 14511) 2.15 2.11 1.99 1.94
COP at A-15/W35 (EN 14511) 2.68 2.63 2.47 2.43
COP at A-20/W35 (EN 14511) 2.50 2.35 2.33 2.27
SCOP (EN 14825) 4.53 4.45 4.25 4.13
Cooling capacity at A35/W18 max. 2.22 2.02 1.83 1.63
Cooling capacity at A35/W18 partial load 3.96 3.76 2.78 2.58
Cooling capacity at A35/W7 max. 2.11 1.91 1.56 1.36
Cooling capacity at A35/W7 partial load 2.61 2.41 2.00 1.80
Sound emissions
Sound power level for indoor installation (EN 12102) dB(A) 45 45 51 50
Max. sound power level for indoor installation dB(A) 53 51 59 56
Sound power level for indoor installation, silent mode 70% dB(A) 52 50 56 55
Max. sound power level for indoor installation, silent mode dB(A) 45 45 51 49
Sound power level for indoor installation, air intake/discharge (EN
12102)
dB(A) 30/32 29/32 43/48 40/44
Max. sound power level for indoor installation, air intake/discharge dB(A) 46/51 43/48 48/52 47/50
Sound power level for indoor installation, air intake/discharge, silent
mode 70%
dB(A) 45/49 43/48 49/50 44/48
Max. sound power level for indoor installation, air intake/discharge,
silent mode
dB(A) 30/32 29/32 43/48 40/44