EasyManua.ls Logo

STIEBEL ELTRON WPL 09 ICS classic - Control Elements on the IWS

STIEBEL ELTRON WPL 09 ICS classic
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION
Troubleshooting
24 |WPL ICS classic | WPL IKCS classic www.stiebel-eltron.com
17.1 Control elements on the IWS
If the fault cannot be identified using the WPM, the IWS will help
you to troubleshoot.
BA
D0000063997
1
2
3
4
1 Reset button
2 DIP switch (WP-Typ)
3 DIP switch (BA)
4 LEDs
17.1.1 DIP switch
DIP switch (WP-Typ)
The DIP switch (WP-Typ) on the IWS serves to set the relevant
heat pump type.
Factory setting
Compressor mode with electric emergency/booster heater
WP - Typ
ON
1 2 3 4
D0000057054
Check whether the DIP switch is set correctly.
Compressor mode with an external second heat generator
!
Material losses
For operation with a second external heat genera-
tor, do not connect the electric emergency/booster
heater.
If the appliance is operated in dual mode with a second external
heat generator, set the DIP switches as follows.
WP - Typ
ON
1 2 3 4
D0000057055
DIP switch (BA)
Factory setting
BA
ON
1 2 3 4
D0000051579
17.1.2 Light emitting diodes (LEDs)
BA
D0000063997
1
2
1 Reset button
2 LEDs
The following table shows the meaning of the LEDs on the IWS.
LED indicator Meaning
Red LED flashes
Single fault. The appliance shuts down. The appli-
ance restarts after 10 minutes. The LED extinguish-
es.
Red LED illuminates
Multiple faults have occurred. The appliance shuts
down. The appliance only restarts following a reset
on the IWS. This also resets the internal fault coun-
ter. The appliance can be restarted after 10min-
utes. The LED extinguishes.
Green LED (centre)
flashes
The heat pump is initialising.
Green LED (centre) illu-
minates
The heat pump was initialised successfully and the
connection with the WPM is active.
Faults indicated by the red LED:
- High pressure fault
- Low pressure fault
- Central fault
- Hardware fault on the IWS (see fault list in the heat pump
manager commissioning instructions)

Table of Contents