EasyManuals Logo

STIEBEL ELTRON WPL 15 AS User Manual

STIEBEL ELTRON WPL 15 AS
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image


www.stiebel-eltron.com  7

7. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
The tested appliance conforms to IEC 61000-3-11.
The tested appliance conforms to IEC 61000-3-12.
8. Appliance description
The appliance offers frost protection for the connection lines. The
integral frost protection circuit starts the circulation pump in the
heat pump circuit automatically at a condenser temperature of
8°C, and thereby ensures circulation in all water-carrying sec-
tions. If the temperature inside the buffer cylinder drops, the heat
pump starts automatically no later than when the temperature
falls below +5°C.
8.1 Accessories
8.1.1 Required accessories
- WPM heat pump manager
8.1.2 Additional accessories
- FEK remote control
- FET remote control
- FE7 remote control
- HZB 1 ribbon heater
- HZB 2 ribbon heater
- STB-FB high limit safety cut-out for underfloor heating
systems
- SK 1 T-support
- WK 2 wall mounting bracket
- MK 1 mounting bracket
- AS-WP 1 connection set
- AS-WP 2 connection set
9. Preparation
!
D0000060163
The appliance is designed for siting in front of a wall. Observe the
minimum clearances. If the appliance is installed in an open space
or on a roof, protect the air intake side. Do this by erecting a wall
to shield it against the wind.
9.1 Sound emissions
The appliance is louder on the air intake and air discharge sides
than on the two enclosed sides. Take the following information
into account when selecting the installation location.
Note
For details regarding the sound power level, see chapter
"Specification / Data table".
- Lawn areas and shrubs help reduce the spread of noise.
- Noise propagation can also be reduced through dense pali-
sades or similar.
Ensure that the entire appliance frame is in full contact
with the substrate. Uneven substrates can increase sound
emissions.
Ensure that the air intake direction is the same as the dom-
inant wind direction. Air should not be drawn in against the
wind.
Ensure that the air intake and air discharge are never direct-
ed towards noise-sensitive rooms of the house, e.g.bed-
rooms, or neighbouring houses.
Avoid installation on large, echoing floor areas, e.g.tiled
floors.
Avoid installation between reflective building walls. Reflect-
ing building walls can increase the noise level.

Table of Contents

Other manuals for STIEBEL ELTRON WPL 15 AS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON WPL 15 AS and is the answer not in the manual?

STIEBEL ELTRON WPL 15 AS Specifications

General IconGeneral
BrandSTIEBEL ELTRON
ModelWPL 15 AS
CategoryHeat Pump
LanguageEnglish

Related product manuals