Fit the flange (1) 1124 850 4205 in
position.
Seal the end of the impulse hose
with a pointed piece of round stock
(3 mm dia.) or a scriber.
Close the vent screw (1) on the
rubber bulb.
- Pump air into the crankcase with
rubber bulb until the gauge
indicates a pressure of 0.6 bar
(8.7 psi). If this pressure remains
constant for at least 20 seconds,
the crankcase is airtight.
4.2.2 Pressure Test
Connect pressure hose of tester
1106 850 2905 to nipple on test
flange.
Mount the clamp (1)
0000 890 4400.
Push the test flange (1)
1106 850 4201 into position.
Fit sleeves (2) 1127 851 8300.
Fit nuts (3) and tighten down
firmly.