66 FS 240 C, FS 260 C, FS 360 C, FS 410 C, FS 460 C-M
7.5.2 Engine does not start in
position }
Is it possible to start
the engine?
Troubleshooting completed
– Check start detection
(microswitch actuation)
clean if necessary
– Examine switch gear,
clean or replace if
necessary, b 7.4
– Check start detection and
wiring harness, b 7.3
yes
Mechanically
OK?
Are target values
attained?
– Look for a fault in the fuel
path (inlet needle, lever,
spring, membrane),
check engine for leaks,
b 11.4, b 5.2
– Replace switchgear,
b 7.4
yes
no
no
Engine does not start in
position } – engine floods.
Can the flooded engine be
started in position F?
yes
no