EasyManua.ls Logo

Stihl MS 650

Stihl MS 650
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
102 MS 650, MS 660
Component Ohmmeter connection
(use either test lead)
Resistance Ω If faulty
Lead 1 Lead 2 Spec. Actual Cause Remedy
Generator Connector
on yellow
wire
Ground 0.5 0.3...1.0 Generator OK
- Break in wire,
generator damaged
Install new
generator
0 Short circuit –
damaged insulation
Repair
insulation
Generator Connector
on yellow
wire
Connector
on red
wire
1.0 0.8...1.8 Generator OK
- Break in wire,
generator damaged
Install new
generator
0 Short circuit –
damaged insulation
Install new
generator