Remove the control panel (1) and set
down to the rear.
Unscrew the screws (1) and remove.
Place the upper housing (1) to one side.
Detach the cable connector (1).
Remove the cables (1) and (2) from the
cable guides.
Risk of injury!
Do not cut cables at the battery.
Risk of short circuit!
Always disconnect the cables and
remove together with the battery.