SR 5600
English
17
Stop Cock
N Stock cock (1) at right angle to
control handle = closed
N Stock cock (1) parallel to control
handle = open
N Adjust the discharge rate with the
metering knob – not the stop cock.
Metering Knob
N The discharge rate can be infinitely
varied by turning the metering
knob (2) on the nozzle (3).
Position 1 = minimum flow rate
Position 6 = maximum flow rate
The numbers on the metering knob must
be lined up with the lug (4) under the
knob.
Discharge Rate
The discharge rate (l/min) depends on
the metering knob setting and the spray
tube angle.
Discharge rate (l/min) without pressure
pump
Discharge rate (l/min) without pressure
pump, with ULV nozzle
Discharge rate (l/min) with pressure
pump (special accessory)
Discharge rate (l/min) with pressure
pump (special accessory) and ULV
nozzle
Metering Unit
1
0811BA013 KN
2
4
1
6
5
4
3
2
372BA005 KN
3
0811BA019 KN
Spray tube angle
Knob setting - 30° + 30°
1 0,28 0,28 0,2
2 0,92 0,85 0,79
3 2,22 1,73 1,33
4 2,96 2,36 1,75
5 3,41 2,7 2,03
6 3,62 2,91 2,19
Spray tube angle
Knob setting - 30° + 30°
0,5 0,1 0,09 0,08
0,65 0,12 0,12 0,1
0,8 0,16 0,15 0,14
Spray tube angle
Knob setting - 30° + 30°
1,0 0,75 0,74 0,74
1,6 2,12 2,02 1,98
2,0 3,15 3,09 3,06
Spray tube angle
Knob setting - 30° + 30°
0,5 0,19 0,18 0,18
0,65 0,29 0,28 0,27
0,8 0,48 0,47 0,47