Maintenance 5
Maintenance safety instructions
26
Check the main power cable for damages.
27
Check the start-up protection during charging.
Function
28 Check the horn function.
29
Check the air gap of the electromagnetic brake.
30
Test the emergency braki
ng.
31
Test the reverse and reg
enerative braking.
32
Test the safety (belly) button function.
33
Check the steering function.
34
Check the lifting and lowering function.
35 Check the tiller arm switch function.
General
36
Check if all decals are legible and complete.
37
Carry out a test run.
.
Technical inspection and maintenance characteristics
Assembly
Item / Lubrica
nt
Capacities / Set
ting Values
Hydraulic Oi
l
0.7L to 1.0L
Main hydraulic system
Maximum press
ure
130 bar
Air gap of the electromagnetic
brake
0.3mmto0.35mm
Brake
Install screw tightening torque
2.8 N.m
FU 10 A
FU01 60 A
FU02 60 A
FU1 10 A
Fuses
FU2 0.5A
.