This information is relevent to the
following appliances:
Stoves 1100DFa
Stoves Precision 1100DFa
Stoves Heritage 1100DF
Data badge - Located on the lower part
of the front frame.
Type of gas - This cooker must only be
used with either Natural gas only or LP gas
only, as specified on the appliance data
badge.
Gas category
Natural gas - I
2H
, LP gas - I
3+
Pressure setting
G20 Natural gas @ 20 mbar
G30 Butane @ 28-30 mbar
G31 Propane @ 37 mbar
Aeration - Fixed
Appliance class - Class 1, freestanding
cooker
Electrical supply
220 - 240V ~ 50Hz
Warning: This cooker must be earthed.
Spark generators
Mains powered 7 outlet, controlled by a
single switch at the left of the fascia to
individual electrodes.
Hob - Burners have burner heads and
caps which are removable for cleaning.
Concealed electrodes to each burner.
Countries of destination
GB - Great Britain, IE - Ireland
25
Hotplate burner / Element Nominal Injector Butane Propane
Rate Qn marking g/h g/h
Natural Hob - small (2) 1.0kW 77 - -
Gas Hob - medium (3) 2.0kW 104 - -
Hob - large (1) 3.0kW 129 - -
Hob - wok (1) 3.5kW 121 & 63 - -
Total heat input Qn 14.5kW
LP Gas Hob - small (2) 1.0kW 50 73 72
Hob - medium (3) 2.0kW 70 145 143
Hob - large (1) 3.0kW 87 218 215
Hob - wok (1) 3.5kW 87 & 35 254 250
Total heat input Qn 14.5kW - 1054 1037
Electric Grill (dual) 2575W - - -
@ 230V Grill (single) 1655W - - -
Conventional oven 1920W - - -
Fan oven 2300W - - -
Stir fan 30W - - -
Cooling fan 10W - - -
Oven lights (if fitted) 25W each - - -
Maximum load 6885W
TECHNICAL DATA
25211 03 - Precision 1100DFa 5/8/04 11:46 AM Page 27