Remedying Faults in PP 1207Klöckner ller
Remedying faults PP 1207
page 10 April 2005
Problem Reason Remedy
1.2 Motor has no function
(control function present)
A. One or more phases
not present
Check if all phases exist.
B. Motor protection
switch has tripped
Check motor protection
switch and change if
necessary; check power
input
C. Motor contactor faulty Change motor contactor
D. Lead to motor faulty Check power lead to
motor
E. Motor faulty Test motor and replace if
necessary