Remedying Faults in PP 1207–Klöckner Möller
Remedying faults PP 1207
page 29 –April 2005
4. Bale cannot be ejected
Problem Reason Remedy
4.1 Bale cannot be
ejected
A. Door is not opened wide
enough
Open door, opening angle
>100°
B. Top of press plate -limit
switch faulty
Test limit switch and replace
if necessary
C. Door limit switch faulty Test limit switch and replace
if necessary
D. Valve sticking Actuate valve manually and
replace if necessary
E. Coil plug faulty Test plug and replace if
necessary
F. Valve coil faulty Test coil and replace if
necessary
G. Ejector lever broken Check ejector lever for
damage and replace if
necessary
PDF wurde mit pdfFactory-Prüfversion erstellt. www.context-gmbh.de