Remedying Faults in PP 1207Klöckner ller
Remedying faults PP 1207
page 20 April 2005
2. Machine does not run in automatic mode
Problem Reason Remedy
2.2 Machine breaks down
after running for short
period
A. Magnetic switch at press
plate and door misaligned or
faulty
Check magnetic switch
and replace if necessary.
2.3 Machine does not start A. Emergency stop enabled Check if emergency stop
switch is engaged
B. Fuse (F1.1 ABB) (F3
KLM) faulty
Check and replace fuse
C. Magnetic switch
misaligned or faulty.
Check switch and adjust
or replace if necessary
D. Relay (K1.12 ABB) (K2
KLM) faulty
Test relay and replace if
necessary
E. Evaluation unit of the
safety switch faulty
Check and replace if
necessary