OVERVIEW / TYPE / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING / PLUGS - PAGE 2 of 2
CAUTION! ADVERSE CONDITIONS / SPACING ISSUES
 Performance issues caused by adverse conditions are NOT warranted.
 End panels must be tightly joined or kept at least 6-inches away from
any structure to prevent condensation.
 Unit must be kept at least 15-feet from exterior doors, overhead HVAC
vents or any air curtain disruption to maintain proper temperatures.
 Unit must not be exposed to direct sunlight or any heat source
(ovens, fryers, etc.).
 Tile floors, low ceilings or small rooms increase noise level. Whisper
Cool compressor blankets or remote units resolve noise level issues.
 Keep at least 8-inch clearance above unit for air discharge
(self-contained units only).
CAUTION
CAUTION! LAMP REPLACEMENT GUIDELINES
Fluorescent lamps have been treated to resist breakage and
must be replaced with similarly treated lamps.
LED lamps reflect specific size, shape and overall design.
Any replacements must meet factory specifications.
CAUTION
PRECAUTIONS
 This sheet contains important precautions to prevent
damage to unit or merchandise.
 Please read carefully!
 See previous page for specifics on OVERVIEW,
TYPE, COMPLIANCE and WARNINGS.
WIRING DIAGRAM
 Each case has its own wiring diagram folded and in
its own packet.
 Wiring diagram placement may vary; it may be
placed near ballast box, field wiring box, raceway
cover, or other related location.
CAUTION! CHECK EVAPORATOR PAN POSITION AND PLUG
Water on flooring can cause extensive damage!
Before powering up unit, check the following:
 Evaporator pan MUST BE positioned directly under condensate drain.
 Evaporator pan plug MUST BE securely plugged into receptacle.
CAUTION! POWER CORD AND PLUG MAINTENANCE
Risk of electric shock. If cord or plug becomes damaged,
replace only with cord and plug of same type.
CAUTION! GFCI BREAKER USE REQUIREMENT
If N.E.C. (National Electric Code) or your local code
requires GFCI (Ground Fault Circuit Interrupter) protection,
you MUST use a GFCI breaker in lieu of a GFCI receptacle.