Section 3
SPECIFICATIONS
14
SULLAIR SERIES 12 AND 16 SPECIFICATIONS (continued)
MOTOR: (50 Cycle Compressors)
Size 40-50-60 and 75 HP 40-50-60 and 75 HP
Type C-Flanged, Open Dripproof, 380V, C-Flanged, Open Dripproof, 380V,
A.C., Three Phase, 50 Cycles A.C., Three Phase, 50 Cycles
40ºC Maximum Ambient Temperature 40ºC Maximum Ambient Temperature
Starter 460V Full Voltage Magnetic 460V Full Voltage Magnetic
Speed 1500 RPM 1500 RPM
LUBRICATION GUIDE-STANDARD COMPRES-
SORS
Sullair standard compressors are filled with SRF
1/4000 fluid factory fill. MIXING OF OTHER FLU-
IDS WITHIN THE COMPRESSOR WILL VOID
ALL WARRANTIES.
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particle level, corrosive gases or strong oxidiz-
ing gases are present in the air.
For extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of all other components is still recom-
mended as indicated in the Operator’s Manual.
LUBRICATION GUIDE-24KT COMPRESSORS
Sullair 24KT compressors are filled with a lubricant
which rarely needs to be changed. In the event a
change of fluid is required, use only Sullair 24KT
fluid. MIXING OF OTHER LUBRICANTS WITHIN
THECOMPRESSOR UNITWILL VOIDALL WAR-
RANTIES!
Sullair recommends that a 24KT sample be taken at
the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with in-
structions and self-addressed container is to be
supplied by your Sullair Representative at start-up.
The user will receive analysis report with recom-
mendations.
APPLICATION GUIDE
Sullair encourages the user to participate in a oil
analysis program with the oil suppliers. This could
result in an oil change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.