5.3
LCD DISPLAY
The display's normal view shows the compressor 
package's discharge pressure, internal temperature, and 
the operating mode. The modes are MANUAL, OFF, 
AUTOMATIC, or FAULTED.
SA_0000005R01
Figure 5-2: 
Refer to Figure 5-2 and Figure 5-3. The lower line is 
occasionally interrupted to describe the compressor 
package's operating state.
SA_0000004R01
Figure 5-3: 
Refer to Figure 5-4. If a machine fault occurs, the red fault 
" " indicator will light up, and the display will indicate that 
a fault has occurred.
SA_0000001R01
Figure 5-4: 
Refer to Figure 5-5. The lower line periodically will display 
the cause of the fault. Refer to service instructions to 
correct the cause. Press the Stop pad " " to reset the 
controller.
SA_0000002R01
Figure 5-5: 
Refer to Figure 5-6. Press the Down arrow " " to display 
additional information about the compressor. The upper 
line will indicate "Compressor Status" and the name of the 
temperature, pressure, or other measurement. The lower 
line indicates the present reading.
SA_0000003R01
Figure 5-6: 
Refer to Figure 5-7. When you continue beyond the status 
information, the display will show a list of control settings. 
The upper line will indicate "Show Setting" and the name 
of the setting. The lower line shows the present value.
SA_0000006R01
Figure 5-7: 
Refer to Figure 5-8. To change the setting, press the Enter 
pad " ". The display indicates that you are in a change 
mode with reverse characters. Use the Up " " or Down 
" " arrow keys to change the setting, and press Enter 
again to save the new setting.
SA_0000007R01
Figure 5-8: 
Refer to Figure 5-8. If there is no keypad activity, the 
display will return to normal view in about one minute. If 
the Start or Stop buttons are pressed, the display also 
returns to normal view. If either of these occur, the setting 
will not be altered.
If there are any warnings or recommended service 
instructions, these will be periodically displayed on the 
normal view.
The list of displays may be navigated from either direction 
by using the Up " " or Down " " arrow keys. For 
example, to change language from normal view, press the 
Up arrow pad once, press the Enter key " ", select your 
language, and press Enter again. The number of displays 
varies with compressor model, but will follow this pattern.
SECTION 5
58
3000-4500 Operator’s Manual and Parts List
®SULLAIR®