DE-18 USER MANUAL SECTION 5
72
Notes:
1. CLASS SHUTDOWNS
A ALWAYS ARMED
B ARMED WHEN THE LOCKOUT DELAY
TIMER EXPIRES
B1 ARMED WHEN THE LOCKOUT DELAY
TIMER EXPIRES
S ARMED WHEN IT'S OWN LOCKOUT DELAY
TIMER EXPIRES
S1 ARMED IMMEDIATELY AFTER A FIXED 10
SECOND TIMER AFTER THE “RUN
ENABLE” RELAY IS ENERGIZED
P ARMED WHEN UNIT LOADED AND CLASS
“P” TIMER EXPIRES
2. Loss of an analog is detected when the voltage
drops to 0.63V, current drops to 2.5mA or 32 counts.
3. Extended names of pressure and temperature
points:
P1 = Interstage Discharge Pressure
P2 = Discharge Pressure
P3 = Oil Filter Out Pressure
P4 = Oil Filter In Pressure
T1 = 1st Stage Discharge Temperature
T2 = 2nd Stage Discharge Temperature
T3 = Oil Filter Out Temperature
T4 = 2nd Stage Inlet Temperature
T5 = Discharge Temperature
T6 = Comp Oil Temperature
E
XTENDED DOCUMENTATION:
M Number adjustments are for Qualified Personal
only. Changing these adjustments is insensitive to
automatic operations and should be considered
dangerous or damaging to equipment and personnel.
S
S
SD
AL
LST ANLG P2 SD
LST ANLG P3 AL
TB1-24, 25 & 26 (S547-Port 1-AN4)
Lost analog signal for transducer2
TB1-33, 34 & 35 (S547-Port 1-AN7)
Lost analog signal for transducer2 SD only if both
P3 and P4 are lost)
S AL LST ANLG P4 AL
TB1-15, 16 & 17 (S547-Port 1-AN1)
Lost analog signal for transducer2 SD only if both
P3 and P4 are lost)
S SD LST AN P3/P4 SD
TB1-15, 16 & 17 (S547-Port 1-AN1)
Lost analog signal for transducer2 SD only if both
P3 and P4 are lost)
S AL S#1 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
S AL S#2 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
S AL S#3 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
S AL S#4 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
S AL S#5 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
S AL S#6 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
S AL S#7 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
S AL S#8 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
S AL S#9 COM
Internal (S547-Port 4) (See 4.0)
(Communication failure to Slave after 60 seconds)
Class SD/AL Description Source

Table of Contents