Section 3
SPECIFICATIONS
13
3.2 LUBRICATION GUIDE
For best value and longest uninterrupted service,
theES---8compressorpart oftheIntegralCompres-
sor/Dryer package is factory filled and tested w ith a
long life lubricant.
WARNING
!
Mixing of other fluids within the compressor will
void all warranties.
If, due to unavailability or other reasons, otherfluids
are required, follow Lubrication Guide below.
WARNING
!
“The Plastic Pipe Institute recommendsagainstthe
use of thermoplastic pipe to transport compressed
air or other compressed gases in exposed above
groundloca tions,e.g.in exposedplantpiping.” (I)
Sullube 32 shouldnotbeusedwithPVC pipingsys-
tems.Itmay affectthebondatcemented joints.Cer-
tain other plastic materials may also be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Maintenance of allother components is stillrecom-
mended as indicated in the Operator’s Manual.
For light---duty high---humidity service where con -
densed moisture and emulsification (mayonnaise)
may occur, the fluid change interval must be re -
duced t o 300 hours maximum. A non---detergent
fluid w ith rust, oxidation and foam inhibitors and
good water separation characteristics should be
used.
WARNING
!
Mixing of other fluids within the compressor will
void all warranties.
Contaminationofnon---detergentmineralfluidswith
traces of ATF or detergent motor fluids may lead to
operational problems such as foaming, filter plug-
ging, orifice or line plugging.
NOTE
Flush system when switching lubricant brands.
When ambient conditions exceed those noted or if
conditionswarrant use of“extended” lifelubricants,
contact Sullair for recommendation.
Sullair encourages the user to participate in a fluid
analysisprogram.Thiscouldresultina fluidchange
interval that is different from those stated in this
manual.
3.3 LUBRICATION CHANGE RECOMMENDATIONS
AMBIENT
TEMPERATURE LUBRICATION
FLUID CHANGE
PERIOD (HRS.)
FILTER CHANGE
PERIOD (HRS.)
--- 10_Fto+90_F SRF 1/4000 (Std. Fill) 4000 4000
( --- 23_Cto+32_C) Sullube 32 8000 (I) 8000 (I)
Sullair LLL---4---32 8000 (I) 8000 (I)
Food Grade CP---4600---32---F 8000 (I) 8000 (I)
(I) 8000 hours or once a year.