Automatic recovery from power failure does not function under default settings.
It is possible to set automatic recovery from power failure by using the control panel.
Operate the switches on the control panel as shown below in order to automatically recover from power 
failure.
18
Operation (continued)
 ● When operating in automatic power recovery, the air compressor will start automatically when the
    main power supply returns. Make sure to press the Stop switch before turning off the main power
    supply when conducting maintenance.
 ● In the case of a power failure, turn off the main power supply. Be aware that residual pressure may
    exist even though there is not a digital display.
 ● When restarting the operation of the air compressor, turn on the main power supply and verify the
    operation control mode before pressing the Start switch.
WARNING
   Digital Display    Start Switch    Stop Switch
Steps Digital Display
1 Verify if the pressure is indicated on the digital display.
2
Press and hold the stop switch for three seconds.
 "P-0" is indicated on the digital display.
3
Press  and  hold the  start  switch  until  "P-1"  is  indicated on  the  digital 
dispiay and power failure automatic recovery is set.
4
To cancel the power failure automatic recovery, carry out steps 1 to 3 
to indicate "P-1" to "P-0" on the digital display.
5 Pressure is again indicated on the digital display after three seconds.
NOTE: Even if the power failure automatic recovery has not been set, the pressure indication will
           return to the digital display after three seconds.