Section 1
SUPERVISOR PROTOCOL
5
(Continued from page 4)
46 T6 CAL (-7 to +7)
47 P2 CAL (-7 to +7)
48 P3 CAL (-7 to +7)
49 P4 CAL (-7 to +7)
50 dP1 CAL(-20 to +10)
51 P3 MAX (-7 to +7)
70 Parameter Protection
(0 = NOT Protected, 1 = Protected)
71 Shutdown on warning
(0 = Warning, 1 = Shutdown)
Parameter protection inhibits the changing of any parameters via the Supervisor keyboard.
This protection can only be enabled and disabled through the serial channel.
The shutdown on warning feature shuts the machine down on alarms that normally only
display a message. This feature can only be enabled and disabled through the serial chan-
nel.
The slave response to the above messages is:
MESSAGE TYPE FORMAT EXAMPLE
p - Parameter changed ##pn,v,xx 01p5,1003D
g - Parameter status ##gn,v,xx 01p5,1003d
d - Display message ##dm,mxx 01d E-STOP, 0 72DE
i - Status info ##id,....,ddxx
q - Quick status ##q1,2,h,r,mxx 01q0,0,E,C66
The parameter changed message sends the value of the parameter back after the change
was attempted. It may not have been changed if it was out of legal range.
Status info message sends the status in the following order:
11. Analog shut/down
12. Digital outputs (BIT 0=K1, BIT 1 =K2, ETC.)
13. Digital shut/down (BIT 0=D1, BIT 1=D2, ETC.)
14. Digital inputs (BIT 0=D1, BIT 1=D2, ETC.)
15. Run Time
16. Load Time
17. Run Status
18. Mode
1. P1
2. P2
3. P3
4. P4
5. T1
6. T2
7. T3
8. T4
9. T5
10. T6