11
Advanced Programming continued
Espresso Thermoblock Temperature
Thewatertemperatureoftheespresso
machinehasbeencalibratedtotheprecise
temperatureof92°Catthegrouphead.
Howeverthecoffeemakercanadjustthe
temperatureofthewateratthegrouphead
inincrementsof2°Cupanddown,shouldit
bedesired.
1.Ensuretheespressomachineispluggedin
andswitchonatthepoweroutlet.
Note:DONOTpressthePOWERbuttonon
theespressomachine.
2.PRESSandholddownthe1CUPbutton.
3.Whilestillholdingdownthe1CUPbutton
brieflyPRESSthePOWERbuttonandthen
releasethe1CUPbutton.
Toindicateyouhaveactivatedthe
programmabilityoftheespressothermoblock
temperature,alightononeofthebuttons
willilluminate;
1CUP=Factorysetting
2CUP=+2°C
PROGRAM=+4°C
MANUAL=-2°C
POWER=-4°C
Thislightwillremainonforupto5seconds
beforeautomaticallyreturningtofactory
settingsifnoactionistaken.Theespresso
machinewillthenpoweron.
4.PRESSandRELEASEoneofthebuttons
belowdependingontherequired
temperatureadjustment;
+2°C=PRESSthe2CUPbutton
+4°C=PRESSthePROGRAMbutton
-2°C=PRESStheMANUALbutton
-4°C=PRESSthePOWERbutton
Whenthenewtemperaturesettinghasbeen
selectedtheespressomachinewillbeep
twice.
5.Theespressomachinewillthen
automaticallypoweron.
Steam Thermoblock Temperature
Thesteamtemperatureofthisespresso
machinehasbeencalibratedtodelivera
powerful,constantsupplyofdrysteamfor
texturingmilk.Thetemperatureofthesteam
canbemodifiedinincrements.of5°Cup
anddownshoulditbedesired.
1.Ensuretheespressomachineispluggedin
andswitchonatthepoweroutlet.
Note:DONOTpressthePOWERbuttonon
theespressomachine.
2.PRESSandholddownthe2CUPbutton.
3.Whilestillholdingdownthe2CUPbutton
brieflyPRESSthePOWERbuttonandthen
releasethe2CUPbutton.
Toindicateyouhaveactivatedthe
programmabilityofthesteamthermoblock
temperature,alightononeofthebuttons
willilluminate;
1CUP=Factorysetting
2CUP=+5°C
PROGRAM=+10°C
MANUAL=-5°C
POWER=-10°C
-4ºC -2ºC
Factory
Setting
+2ºC +4ºC