Operation Instruction
SR81Q
Intelligent Controller
for Split Pressurized Solar Hot Water System
Please read this instruction carefully!
Question and Answer IconNeed help?

Do you have a question about the SUNFLOWER SR81Q and is the answer not in the manual?

SUNFLOWER SR81Q Specifications

General IconGeneral
BrandSUNFLOWER
ModelSR81Q
CategoryController
LanguageEnglish

Summary

Safety Information

1.1 Installation and commissioning

Guidelines for wiring and safe installation practices.

1.2 About this manual

Explains the purpose and scope of the manual.

1.3 Liability waiver

Manufacturer's disclaimer regarding improper installation or use.

Safety Information

1.4 Important information

General notes and potential errors in the manual.

1.5 Signal description

Explains symbols used for safety and operation instructions.

1.6 Button and HMI description

Identifies and describes the controller's buttons and display elements.

Overview

2.1 Technical data

Lists key technical specifications of the controller and its inputs/outputs.

Installation

3.1 Mounting the display of controller

Instructions for physically attaching the controller display unit.

3.2 Mounting the board of controller

Instructions for mounting the main controller board.

3.3 Preparation before wiring connection

Steps to prepare for electrical connections.

3.4 Wiring connection

General guidelines for making electrical connections.

Installation

3.5 Terminal connection

Details on connecting wires to controller terminals.

3.6 R3 output connection with T- valve; pump

Specific wiring instructions for R3 output with valves or pumps.

3.7 Connection with high efficiency pump

Wiring instructions for connecting high-efficiency pumps.

Installation

Advice regarding the installation of temperature sensors

Best practices for installing temperature sensors to ensure accuracy.

System description (Standard solar system with 1 tank, 1 collector field)

Time setup

Functions parameters and options

6.1 Overview of menu structure

Visual representation of the controller's menu hierarchy and functions.

6.2 Menu operation description

How to navigate through the controller's menus and adjust settings.

6.3 Value checking and function checking

How to view current system values and check function status.

Functions operation and parameters setting (for user)

7.1 THET Timing heating

Configuration for timed heating cycles based on temperature.

7.2 CIRC DHW circulation pump controlled by temperature and time

Setting up the domestic hot water circulation pump.

Function operation and parameter setup (engineer)

8.1 PWD Password

How to set or change the controller's access password.

8.2 LOAD tank heating

Configuration for tank heating based on temperature differentials and pump speed.

8.3 COL Collector function

Settings related to collector operation and protection.

OCEM (Collector emergency shutdown function) setup

Configuration for the collector emergency shutdown function.

OCMI (Collector minimum temperature) setup

Configuration for the collector minimum temperature function.

OCFR (Antifreeze function) setup

Configuration for the collector antifreeze function.

OTCO (Tube collector function) setup

Configuration for the tube collector function.

8.4 PUMP Pump control mode

Settings for controlling pump operation and speed.

8.5 COOL Cooling function

Configuration for various cooling functions of the solar system.

OSYC (System cooling) setup

Setup for the system cooling function.

OSTC (Tank cooling) setup

Setup for the tank cooling function.

OHDP (Heat transferring) setup

Setup for heat transferring by external radiator.

8.6 AUX Auxiliary function

Settings for auxiliary functions like timers and thermostats.

8.7 MAN Manual operation

How to manually control the controller's relays.

8.8 BLPR Blocking protection

Function to protect pumps from blocking during standstill.

8.9 OTDI Thermal Sterilization Function

Prevents Legionella spread by sterilizing DHW tanks.

8.10 OPAR Parallel relays

Enables parallel control of a motor valve or pump using separate relays.

8.11 OHQM Thermal energy measuring

Methods for measuring thermal energy produced by the solar system.

8.12 FS Flow meter option and flow rate monitoring

Configuration and monitoring of flow meters.

8.13 UNIT Switch

Setting temperature and thermal energy units (Celsius/Fahrenheit, kWh/BTU).

8.14 RET Reset

Restoring controller parameters to factory default settings.

8.15 PASS Password set

Setting or recovering the controller's password.

8.16 Manual heating

Manually triggering backup heating for the tank.

8.17 ECO Economic mode

Energy-saving mode that disables certain heating functions.

8.18 DHW circuit pump triggered manually

Manually activating the DHW circulation pump.

8.19 On;Off controller

Instructions for switching the controller on and off.

8.20 Holiday function

Function to reduce thermal load during periods of absence.

8.21 Manual circuit function

Manually activating the circuit pump for a set duration.

Protection function

9.1 Memory function during power failure

How settings are retained during power outages.

9.2 Screen protection

Automatic screen dimming and protection feature.

Trouble checking

Quality Guarantee

Accessories

Related product manuals