113
Parameters
SG30CX
(5)
SG50CX
(5)
Surge Protection
DC Type II / AC Type II
Protective Class
I
Overvoltage Category DC II / AC III
Active Anti-Islanding
Method
Frequency Shift
General Data
Dimensions (W×H×D)
702×595×310mm 782×645×310 mm
Weight
50 kg 62 kg
Topology Transformerless
Degree of protection
IP66
Night power
consumption
≤2 W
Operating ambient tem-
perature range
-30 ~ 60 (> 45 derating)
Allowable relative humid-
ity range
0 ~ 100%
Cooling method
Smart forced air cooling
Max. operating altitude
4000 m (> 3000 m derating)
Display
LED, Bluetooth + App
Communication
RS485 / WLAN / Optional: Ethernet
DC connection type
MC4 (Max. 6 mm
2
)
AC connection type
OT or DT terminal (Max.70 mm
2
)
Grid Support
Q at night function, LVRT, HVRT, active & reactive power con-
trol and power ramp rate control
Country of manufacture China
Note(5): For Australia.
Note(6): The inverter enters the standby state when the input voltage ranges between 1,000
V and 1,100 V. If the maximum DC voltage in the system can exceed 1000 V, the MC4 con-
nectors included in the scope of delivery must not be used. In this case MC4 Evo2 connec-
tors must be used.
Note(7):
The voltage difference between MPPTs should be less than 80 V.
The voltage of the configured string should be higher than the lower limit of the rated
MPPT voltage.
User Manual 10 Appendix

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG30CX-NI and is the answer not in the manual?

Sungrow SG30CX-NI Specifications

General IconGeneral
BrandSungrow
ModelSG30CX-NI
CategoryInverter
LanguageEnglish

Related product manuals