User Manual 1 Safety
3
Warning Label
Label
Description
Disconnect the inverter from all the external power sources
before service!
Do not touch live parts until 10 minutes after disconnection
from the power sources.
There is a danger from a hot surface that may exceed
60 °C.
Danger to life due to high voltages!
Only qualified personnel can open and service the inverter.
Check the user manual before service!
* The warning label in English has been pasted before delivery. The labels in
other languages are included in the delivery contents and users may paste the
corresponding label according to specified need.
1.4 Skills of Qualified Personnel
All installations should be performed by qualified personnel. They should have:
training in the installation and commissioning of the electrical system, as well
as the dealing with hazards
knowledge of the manual and other related documents
knowledge of the local regulations and directives

Table of Contents

Other manuals for Sungrow SG5K-D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG5K-D and is the answer not in the manual?

Sungrow SG5K-D Specifications

General IconGeneral
Rated AC Output Power5000 W
Max. Efficiency98.4%
Operating Temperature Range-25°C to +60°C
Max. DC Power6000 W
Number of MPPTs2
Max. AC Power5500 VA
Rated AC Voltage230 V
AC Voltage Range180 V - 280 V
Rated Grid Frequency50 Hz / 60 Hz
Power Factor at Rated Power>0.99
THDi<3%
DC Connection TypeMC4
Protection DegreeIP65
Cooling MethodNatural convection
AC Connection TypePlug-in terminal