Do you have a question about the Sungrow SG50CX-P2 and is the answer not in the manual?
Rated Power | 50 kW |
---|---|
Max. DC Voltage | 1100 V |
MPPT Voltage Range | 200 V - 1000 V |
Max. Input Current per MPPT | 26 A |
Number of DC Input Terminals per MPPT | 2 |
Rated AC Output Power | 50 kW |
Max. AC Output Power | 55 kW |
AC Nominal Voltage | 400 V |
AC Voltage Range | 310 V - 480 V |
AC Grid Frequency | 50 Hz / 60 Hz |
Grid Frequency Range | 45 Hz - 55 Hz / 55 Hz - 65 Hz |
Total Harmonic Distortion | <3% |
DC Switch | Yes |
Protection Class | I |
Cooling Method | Smart Forced Air Cooling |
Protection Degree | IP66 |
Maximum Efficiency | 98.7% |
Topology | Transformerless |
Power Factor at Rated Power | 0.8 leading to 0.8 lagging |
Operating Temperature Range | -25°C to +60°C |
Communication | RS485, Ethernet |
Covers safety during installation, electrical connections, and operation. Includes warnings and precautions.
Details safety protocols for inverter maintenance, including high-voltage operations and cooling down periods.
Covers safety during mounting, location, carrier, angle, and clearance requirements.
Emphasizes critical safety instructions for all electrical connections.
Provides requirements and procedures for connecting AC cables to the inverter.
Outlines safety, configuration, and connection procedures for DC cables.
Details the steps for starting up the inverter and initial grid connection.
Lists common fault codes, names, and corrective measures for inverter issues.