Step 3 Tap More→Firmware Download to enter corresponding interface on which you can view
the device list.
Step 4 Select the device model before downloading the firmware. Tap the device name in the device
list to enter the firmware upgrade package detail interface, and tap
behind the firmware
upgrade package to download it.
Step 5 Return to the Firmware Download screen, tap in the upper right corner of the interface
to view the downloaded firmware upgrade package.
Step 6 Login the App via local access. Refer to "7.4.2 Login Procedure".
Step 7 Tap More on the App home page and then tap Firmware Update.
Step 8 Tap the upgrade package file, a prompt box will pop up asking whether to upgrade the firm-
ware with the file, tap CONFIRM to perform the firmware upgrade.
Step 9 Wait for the file to be uploaded. When the upgrade is finished, a message is displayed indi-
cating that the upgrade is completed. Tap Complete to end the upgrade.
- - End
7.6.6 Grounding Detection
Contact your distributor to obtain the advanced account and corresponding pass-
word before setting the earth detection parameters. If the distributor is unable to
provide the required information, contact SUNGROW.
Unauthorized personnel are not allowed to log in with this account. Otherwise,
SUNGROW shall not be held liable for any damages caused.
7 iSolarCloud App User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX-P2 and is the answer not in the manual?

Sungrow SG50CX-P2 Specifications

General IconGeneral
Rated Power50 kW
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of DC Input Terminals per MPPT2
Rated AC Output Power50 kW
Max. AC Output Power55 kW
AC Nominal Voltage400 V
AC Voltage Range310 V - 480 V
AC Grid Frequency50 Hz / 60 Hz
Grid Frequency Range45 Hz - 55 Hz / 55 Hz - 65 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassI
Cooling MethodSmart Forced Air Cooling
Protection DegreeIP66
Maximum Efficiency98.7%
TopologyTransformerless
Power Factor at Rated Power0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to +60°C
CommunicationRS485, Ethernet

Related product manuals