93
Tap More→Settings→Operation Parameters→Grounding Detection to enter the corre-
sponding screen.
figure 7-22 Grounding Detection
If the grounding detection is enabled, the DO relay will switch on automatically to signal the
external alarm if the value exceeds the grounding detection alarm value.
The PV insulation resistance fault (fault sub-code 039) will trigger the DO relay to signal the
external alarm.
7.6.7 Password Changing
Tap Modify Password to enter the modify password interface, as shown in the following
figure.
figure 7-23 Modify Password
The password shall consisit of 8–20 digits, including letters and numbers.
User Manual 7 iSolarCloud App

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX-P2 and is the answer not in the manual?

Sungrow SG50CX-P2 Specifications

General IconGeneral
Rated Power50 kW
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of DC Input Terminals per MPPT2
Rated AC Output Power50 kW
Max. AC Output Power55 kW
AC Nominal Voltage400 V
AC Voltage Range310 V - 480 V
AC Grid Frequency50 Hz / 60 Hz
Grid Frequency Range45 Hz - 55 Hz / 55 Hz - 65 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassI
Cooling MethodSmart Forced Air Cooling
Protection DegreeIP66
Maximum Efficiency98.7%
TopologyTransformerless
Power Factor at Rated Power0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to +60°C
CommunicationRS485, Ethernet