7.7.2 Create a Plant
Requirements
The matching communication device for the inverter has been properly installed.
There are available wireless home networks, and your mobile phone has connected to a
wireless home network.
You have already logged in to the iSolarCloud App. You can create an iSolarCloud
account by yourself, or contact your distributor/installer or SUNGROW for the account
and password.
Devices are managed as part of a plant on the iSolarCloud App. You can add different types
of devices to the plant, e.g., inverters, batteries, and communication modules. The following
three steps are required to create a plant: "7.7.2.1 Complete Plant Information", "7.7.2.2 Add
Communication Device & Set up Network Connection", and "7.7.2.3 Set Tariffs".
7.7.2.1 Complete Plant Information
Background Information
User interfaces for creating a plant may differ slightly by the plant type, inverter type, or com-
munication device. Please refer to the interfaces actually shown on the App. Some of the re-
quired information need to be acquired in advance, for example:
To authorize the Distributor/Installer to manage the plant, the Owner needs to ask them
for their distributor/installer code.
To assist the Owner in creating a plant, the Distributor/Installer needs to ask for the own-
er's phone number.
User Manual 7 iSolarCloud App

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX-P2 and is the answer not in the manual?

Sungrow SG50CX-P2 Specifications

General IconGeneral
Rated Power50 kW
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of DC Input Terminals per MPPT2
Rated AC Output Power50 kW
Max. AC Output Power55 kW
AC Nominal Voltage400 V
AC Voltage Range310 V - 480 V
AC Grid Frequency50 Hz / 60 Hz
Grid Frequency Range45 Hz - 55 Hz / 55 Hz - 65 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassI
Cooling MethodSmart Forced Air Cooling
Protection DegreeIP66
Maximum Efficiency98.7%
TopologyTransformerless
Power Factor at Rated Power0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to +60°C
CommunicationRS485, Ethernet