72
Systems equipped with SUNGROW optimizers can only work with SUNGROW com-
munication devices and iSolarCloud App. Please use V2.1.6.20230411 or later ver-
sions of iSolarCloud App.
7.3 Function Overview
The App provides parameter viewing and setting functions, as shown in the following figure.
figure 7-1 App Function Tree Map
7.4 Device Initialization
7.4.1 Requirements
The following requirements should be met:
The AC or DC side of the inverter is powered-on.
The mobile phone is within 5 meters away from the inverter and there are no
obstructions in between.
The Bluetooth function of the mobile phone is enabled.
The inverter can only pair with one phone at a time through Bluetooth.
7 iSolarCloud App User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX-P2 and is the answer not in the manual?

Sungrow SG50CX-P2 Specifications

General IconGeneral
Rated Power50 kW
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of DC Input Terminals per MPPT2
Rated AC Output Power50 kW
Max. AC Output Power55 kW
AC Nominal Voltage400 V
AC Voltage Range310 V - 480 V
AC Grid Frequency50 Hz / 60 Hz
Grid Frequency Range45 Hz - 55 Hz / 55 Hz - 65 Hz
Total Harmonic Distortion<3%
DC SwitchYes
Protection ClassI
Cooling MethodSmart Forced Air Cooling
Protection DegreeIP66
Maximum Efficiency98.7%
TopologyTransformerless
Power Factor at Rated Power0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to +60°C
CommunicationRS485, Ethernet