Timer Maintenance
Your SunQuest
®
sunbed is equipped with a
backup shut-off timer which will automat-
ically turn off the sunbed in the unlikely
event of a malfunction of the primary
timer. This important safety feature also
prevents the user from re-setting the timer
before the end of the pre-set maximum
time interval. The electronic timer limiting
circuit is automatically reset each time the
primary timer is turned to the OFF posi-
tion.
Annually, or whenever your sunbed is re-
lamped, check the operation and accura-
cy of the timer system as follows. DO
NOT perform these tests with a person in
the sunbed.
Step 1 Obtain an accurate watch capa-
ble of measuring in seconds. Set
the timer to its maximum inter-
val. Using the watch, time how
long the lamps remain on. The
lamps should shut off within
plus or minus 10% of the maxi-
mum timer interval.
Step 2 Set the timer to the maximum
time interval. Wait ten minutes,
then turn the knob back to the
maximum time position. The
electronic time limiting circuit
should turn the lamps off at an
elapsed time equal to approxi-
mately 10% beyond the maxi-
mum timer interval, even
though the primary timer con-
tinues to show time left.
Call ETS Customer Service if your timer
does not operate properly, or if you expe-
rience difficulty with these tests.