5.2.4 The demanded quality of water
The bad quality water will produce more scale and sand, so this kind of water should be filtered and
demineralized.
The water quality should be analyzed before system running, to measure the PH value,
conductivity, Chloride ion concentration and sulphate ion concentration.
The acceptable water quality standard is showed as below table.
PH value
Total hardness
Conductivity
Sulphate ion
Chlorine ion
Ammonia ion
78.5
< 50ppm
<200μV/cm(77)
None
< 50ppm
None
Sulfate ion
Silicon
Iron content
Sodium
Ca
< 50ppm
< 50ppm
< 0.3ppm
No requirement
< 50ppm
Suggest the filter meshes is about 40 meshes.
Must install the sand filter, hair collector etc. Swimming pool special impurity filter equipment.
6. Installation of optional accessories
6.1 Selection of the water pump
The circulation pump is needed for the system, the power port is prepared for the pump, (one
phase)
NOTE
For the single phase pump, please check the circuitry diagram.
The head of circulation pump = height difference between water level and main unit + total
pipelines resistance (determined by the hydraulic calculation) + pressure loss of main unit (see the
nameplate on heat pump ).
NOTE
when multi paralleled, the water pump head is subject to the worst working condition loop.