5.2.4 The demanded quality of water
● The bad quality water will produce more scale and sand, so this kind of water should be filtered and
demineralized.
● The water quality should be analyzed before system running, to measure the PH value,
conductivity, Chloride ion concentration and sulphate ion concentration.
● The acceptable water quality standard is showed as below table.
● Suggest the filter meshes is about 40 meshes.
● Must install the sand filter, hair collector etc. Swimming pool special impurity filter equipment.
6. Installation of optional accessories
6.1 Selection of the water pump
● The circulation pump is needed for the system, the power port is prepared for the pump, (one
phase)
NOTE
For the single phase pump, please check the circuitry diagram.
● The head of circulation pump = height difference between water level and main unit + total
pipelines resistance (determined by the hydraulic calculation) + pressure loss of main unit (see the
nameplate on heat pump ).
NOTE
when multi paralleled, the water pump head is subject to the worst working condition loop.