2
G:\布谷鸟\伍伟键(you)\杂项\YQ01-2.bmp
N 1L
Compressor
Capacitor
Terminal
PCB
Fan motor
Capacitor
4# Wire press buckle
Screw out the bolt and open
this front panel, will find the
main control board and
terminal block.
7. Installation of electric devices
7.1 Electrical wiring
The unit should use a dedicated power supply, power supply voltage with rated voltage.
Unit power supply circuit must be ground, power supply wire and external grounding reliable
connection, and the external grounding is effective.
Wiring must be constructed by the professional installation technicians in accordance with the
circuit diagram.
Power line and signal line layout should be neat, reasonable, can not interfere with each other, but
not with the connecting pipe and the valve body contact.
If the unit is not matching the power line, please supply specifications refer to provisions, wires
connecting is not allowed.
After all wiring construction is completed, please check it before switch on the power supply
carefully.
Figure 11
Figure 12 Electrical Box