4)Real time clock settings:
In the main interface, click the “ ” button to enter the real-time clock setting interface; In the
real-time clock interface, press the “ ” button, the hour part of the number flashes, press “
∧
” or
“
∨
”, you can Set the hour of the clock; when the hour part is set, press the “Time” button again, the
number of minutes will flash, press “
∧
” or “
∨
” to set the minute of the real time clock; After the
minute part is set, press the “ ” button again to confirm the real-time clock setting and return to
the main interface;
In the real-time clock setting interface, if there is no button operation for 5 seconds, the current
real-time clock setting value is confirmed, and the main interface is returned;
In the real-time clock setting interface, press the “ ” button to confirm the current real-time clock
setting value and return to the main interface.
5)Timing work settings:
Press and hold the “ ” button for 3 seconds in the main interface to enable or disable the timed
working mode. When the timed working mode is enabled, enter the timed period setting. Press and
release “ ” to switch the hour and minute of the start time and end time of the three time slots in
sequence., The value is flashing when switching to the corresponding value of the certain time slot.
At the same time, “ON” or “OFF” symbol flashes, Press “
∧
” or “
∨
” to increase or decrease the
corresponding value. After setting the timed period, press and immediately releasing the “switch”
button or no button operation in 15 seconds, the changes can be saved and returned to the normal
display state.
When the timing control mode is enabled, the corresponding symbols are displayed in the working
period (ON) and the non-working period (OFF) respectively. In the power-on state, heating/cooling is
performed only during the set working period, and the rest of the time is not heating/cooling. When
the start time and end time of a certain working period are the same, it is regarded as canceling the
timing period. When all timed periods are cancelled, it is considered to be in working hours
throughout the day. If the start time of a certain working period is greater than the end time, the end
time is considered to be the next day. The three time periods default to 05:00~07:00, 16:00~18:00,
20:00~00:00.
6)Set the cooling/heating mode:
With the controller in normal display, press “ ” to switch between cooling or heating mode.
When switching to the cooling or heating mode, the cooling or heating symbol flashes quickly for 3
seconds and then returns to the normal display state. When switching to the cooling mode, the
temperature judgment automatically selects “manual mode”, and the water temperature can be set at
this time. When the cooling/heating mode is switched, the compressor is allowed to start running
after at least 3 minutes of stopping.