EasyManua.ls Logo

Sunrise spas 670 S - User Manual

Default Icon
164 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SPA OWNERS MANUAL
IMPORTANT SAFETY INSTRUCTIONS
READ & FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Pour voir ou imprimer ce document en Français, veuillez visiter:
http://www.sunrisespas.com
OM-SUNRISE-18E

Table of Contents

Questions and Answers

  • D
    David BakerAug 5, 2025
    Why is the water in my Sunrise spas Hot Tub not hot enough?
    • A
      Alicia RyanAug 5, 2025
      There could be several reasons why your Sunrise spas Hot Tub water isn't hot enough. First, check if the set point is at the desired level and change it if necessary. Ensure the circulation pump is running and that the valves on the circulation pump/heater system are open. Make sure the spa is covered when not in use to retain heat. If an error message is displayed, check for open gate valves, correct the water level, and examine the filter cartridge(s). Turn the spa power off and back on. If the issue persists, contact your dealer. The system input current setting might also be restricting heater operation, so consult with your dealer or electrician. Finally, consider adding insulation to protect the underside of the spa from cold winds or snow.
  • N
    Nicole PattersonAug 9, 2025
    What to do if GFCI/RCD shuts off on Sunrise spas 670 S Hot Tub?
    • J
      Jesse MuellerAug 9, 2025
      If the Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector (RCD) shuts off (not on initial start-up) in your Sunrise spas Hot Tub, it could be due to a short in one or more pieces of equipment or because the total current draw exceeds the GFCI/RCD rating. Contact your dealer and DO NOT use the spa. Take measures to ensure others do not use the spa.
  • D
    Dana AriasAug 13, 2025
    What to do if my Sunrise spas Hot Tub is completely dead?
    • O
      osmithAug 14, 2025
      If your Sunrise spas Hot Tub is completely dead, with no circulation and no display, start by checking if the GFCI/RCD has tripped and reset it. If the problem persists, alert your dealer. Also, check the breaker or fuse before the GFCI/RCD; if tripped or blown, shut off the GFCI/RCD, reset the breaker or replace the fuse, and then reset the GFCI/RCD. If it continues, contact an electrician or your dealer. Another potential cause is a blown transformer fuse in the spa pack, which you can test and replace, or contact your dealer for service. Finally, insufficient line voltage could be the issue, so contact an electrician to measure line voltages and inspect supply connections.
  • J
    Jenna CarterAug 17, 2025
    How to fix Sunrise spas Hot Tub jets not working?
    • G
      gcarrollAug 18, 2025
      If the jets on your Sunrise spas Hot Tub aren't working when you press the pump key, first ensure the jet pump is plugged into the spa pack and test it. Check the jet pump fuse in the spa pack and replace it if blown. If the problem persists, contact your dealer. Also, the jet pump may not be primed; shut off the spa to allow trapped air to escape, then restart it. If problems continue, bleed air at the pump directly. Make sure the individually adjustable volume jets are not set too low and the air control is open. If the pump has overheated, wait for it to cool and reset. If the motor works but there is no water movement, contact your dealer for service.
  • V
    vtaylorAug 22, 2025
    Why is there no air/water mixture coming from a jet in my Sunrise spas 670 S?
    • J
      Jamie ThomasAug 22, 2025
      If there's no air/water mixture coming from a jet in your Sunrise spas Hot Tub, first check if the air control is closed and open it. If the water volume through the jet is too low, increase it by turning the jet face. Also, check if the adjustable jet internal is loose and tighten it. If the jet internal is broken or damaged, replace it. Finally, inspect the jet internal for debris, remove it, and reinstall it.
  • J
    Jenna JonesAug 26, 2025
    What to do if LED lights don't turn on in my Sunrise spas 670 S Hot Tub?
    • W
      Whitney LopezAug 26, 2025
      If the LED lights in your Sunrise spas Hot Tub don't come on when you press the light key, start by checking the light fuse in the spa pack and replace it if necessary. If the problem persists, call your dealer. Also, check the in-line or on-board fuse in the LED controller and replace it if blown.
  • D
    Desiree WalkerAug 30, 2025
    How to fix GFCI/RCD shutting off on initial start-up of Sunrise spas Hot Tub?
    • C
      Christopher JonesAug 30, 2025
      If the Ground Fault Circuit Interrupter (GFCI) or Residual Current Detector (RCD) shuts off on the initial start-up of your Sunrise spas Hot Tub, it may be due to mis-wiring of the GFCI/RCD. Contact an electrician and/or your dealer.

Summary

IMPORTANT SAFETY INSTRUCTIONS

Safety Sign Information

Details about the safety sign and owner responsibilities for its placement and visibility.

General Warnings and Cautions

Covers specific dangers, warnings, and cautions related to spa usage and health.

READ AND FOLLOW ALL INSTRUCTIONS

Hyperthermia Safety Precautions

Explains the risks of hyperthermia, its symptoms, and specific warnings.

SAFETY INSTRUCTIONS FOR SPAS WITH AUDIO SYSTEMS

INSTALLATION INSTRUCTIONS

SPA SUPPORT REQUIREMENTS

ELECTRICAL CONNECTION GUIDELINES

Cable Entry and Routing

Provides guidance on locating conduits and routing supply cables into the spa.

RESIDUAL CURRENT DETECTOR (RCD) INFORMATION

230 VOLT SUPPLY CONNECTION

Spa Pack Model SRBP601 E Wiring

Details the electrical connection for the SRBP601E spa pack model.

SPA PACK WIRING: SRBP21, SRBP21 X, SRBP21 MS

CONVERTING TO 3-SERVICE WIRING

SPA EQUIPMENT IDENTIFICATION

SPA START-UP AND OPERATION

Spa Operation, Heating, and Filtration

Explains how the spa circulates, heats, filters, and operates its basic functions.

FILLING AND STARTING YOUR SPA

TP600 SIMPLIFIED MENUS USER GUIDE

SPA FILLING AND PRIMING PROCEDURES

Priming Mode and Pump Operation

Details the priming mode sequence and how to prime the spa pumps.

Priming Mode and Pump Operation Details

Details the priming mode sequence and operation of spa pumps.

SPA BEHAVIOR AND OPERATING MODES

Freeze Protection and Clean-up Cycle

Explains freeze protection mechanisms and the optional clean-up cycle.

TEMPERATURE SETTINGS AND RANGES

Adjusting Set Temperature

Instructions on how to adjust the spa's set temperature.

FILTRATION AND PURGE CYCLE ADJUSTMENTS

Main Filtration and Filter Cycle 2 Settings

Details on adjusting main filtration and optional filter cycle 2 settings.

GENERAL SPA MESSAGES AND ALERTS

Freeze Protection and High Water Alerts

Describes alerts for freeze protection and water temperature being too high.

HEATER-RELATED MESSAGES AND CHECKS

SENSOR AND MISCELLANEOUS SYSTEM MESSAGES

SYSTEM-RELATED ERROR MESSAGES

QUALIFIED TECHNICIAN REQUIRED FOR SERVICE AND INSTALLATION

Installation and CSA Compliance Guidelines

Provides basic installation guidelines and CSA compliance information.

TP600 REGULAR MENUS USER GUIDE

TEMPERATURE AND RANGE SETTINGS

Adjusting Set Temperature and Ranges

Instructions for adjusting spa temperature and dual temperature ranges.

SPA MODES: READY AND REST

TIME-OF-DAY AND DISPLAY SETTINGS

OPERATION LOCKING AND UNLOCKING

HOLD AND DRAIN MODES

FILTRATION ADJUSTMENT PROCEDURES

GFCI TEST FEATURE UTILITIES

Forcing the GFCI Trip Test Procedure

Instructions on how to manually initiate the GFCI trip test.

UTILITIES: FAULT LOG DETAILS

ACCESSING YOUR FILTER CARTRIDGES

SPA MAINTENANCE PROCEDURES

JET MAINTENANCE AND COVER CARE

FILTER SYSTEM MAINTENANCE

DRAINING YOUR SPA

Spa Draining and Vacuuming Procedures

Guides on when and how to drain the spa and vacuum spa lines.

WINTERIZING YOUR SPA

TROUBLESHOOTING SPA PROBLEMS

GFCI;RCD Trip and Dead Spa Issues

Troubleshooting for GFCI trips and spa being completely dead.

HEAT AND PUMP PERFORMANCE ISSUES

No Heat or Low Heat Troubleshooting

Addresses issues related to the spa not heating or heating insufficiently.

PUMP AND JET OPERATION ISSUES

Jets Not Activating When Pump Pressed

Troubleshooting steps when jets do not operate after the pump is activated.

LIGHT AND AIR;WATER MIXTURE ISSUES

FUSE CHECK AND WARRANTY SERVICE

BP501;601 SERIES SPA PACK WIRING DIAGRAM

BP2000;2100 SERIES SPA PACK WIRING DIAGRAM

WATER TREATMENT GUIDE

Sanitizing and Initial Spa Fill

Procedures for sanitizing spa water and initial filling.

ROUTINE SPA MAINTENANCE SCHEDULE

WATER BALANCE AND pH MANAGEMENT

WATER CHEMISTRY: ALKALINITY AND CALCIUM HARDNESS

COMMON SPA WATER PROBLEMS AND SOLUTIONS

Sunrise spas 670 S Specifications

General IconGeneral
BrandSunrise spas
Model670 S
CategoryHot Tub
LanguageEnglish

Related product manuals