PART NO. 690809 REV: A 29
Troubleshooting
Problem Solution
Lift will not operate with manual
switches on RC box
-Check both Circuit Breakers are on
-Check power on RC box is on
-Check battery voltage
Lift will not operate with Key Fob
Transmitter buttons
-Check that lift operates with manual switches on RC box (see above)
-Check RC box antenna is run to outside of metal Powerpack box
-Re-program Key Fob Transmitter per instructions in manual
-Check battery voltage in Key Fob Transmitter
Key Fob Transmitter has limited
range
-Check RC box antenna is run to outside of metal Powerpack box
-Re-program Key Fob Transmitter per instructions in manual
-Check battery voltage in Key Fob Transmitter
-Hold Transmitter in different location (over head, or different location in boat)
-Proximity to cell phone towers, power lines and other electromagnetic interfer-
ence can also reduce range.
Boat lists to one side when lifting -Check Boat is loaded in center of FloatLift and and is evenly weighted
-Check that both hydraulic pumps are operating (both Circuit Breakers ON).
Single pump operation will not be as level as 2-pump operation
-If lift just installed, air in system will cause uneven lifting. Operate lift for 4
cycles to purge all air from system.
-Check hoses are not crimped or damaged
Fluid found in bottom of Power-
pack
-If lift just installed, air in system often expands and causes fluid to overflow.
Check fluid level after installation is complete and all air is purged from system
-Check for leaks. Tighten hose fittings or reposition gaskets as necessary
Lift stops momentarily -Check for low battery. Key Fob Transmitter will stop functioning with low
Powerpack battery.
The lift can be operated with manual switch on RC box.
The RC stops responding to Transmitter at about 22V
The pump motor stops functioning about 18V
Battery terminal becomes hot -Check battery cable is clean and tight on battery terminal