PART NO. 690809 REV: A 22
FLOATLIFT BASIC OPERATING INSTRUCTIONS (See sticker inside lid of Powerpack)
Conduct Daily Use Inspection as specified on adjacent Maintenance Reminders sticker
Lift can be operated using the up/down buttons on the wireless remotes, or on the buttons on
the RC box.
Verify power is on:
Pump A: Turn on Circuit Breaker A
Pump B: Turn on Circuit Breaker B
RC power: Rocker switch on RC box
To Lower FloatLift:
Press Down button on Key Fob Transmitter or on RC box (small black box inside Power-
pack).
The lift can be lowered just low enough to start engines. Boat can be boarded in this position.
When ready to depart, lower just enough to release boat.
Raise lift if it will not be used for an extended period of time to keep bunks clean.
To Load boat on FloatLift:
If FloatLift is raised, lower lift enough to accept boat
Slowly load boat on lift, and center weight of boat within about 12” of center of lift (fore/aft),
and within 6” of Port/Stbd.
Press the ‘Up’ button and verify fore/aft balance. Front and rear of floats shall be within 4” in
elevation.
Stop part way when floats are in best position for unloading boat.
After unloading, continue ‘Up’ until both port and starboard floats are locked over-center,
with the wheels on the outer downslope of the roller plate ramp
Important:
If lift takes more than 2 minutes to lift (3 minutes for FL36 & FL40), verify both power units
are operating
Max capacity 24,000 lbs for FL24, 36,000 lbs for FL36 & 40,000 lbs for FL40
Max beam 13’ 9”
Inspect lift per operating manual every use and every 6 months
If Solar Charging is used, Solar Panels must be in direct sunlight for at least 6 hours a day
Powerpack must be in safe location on dock
Warnings
Keep people away from moving unit,
Keep hands and feet away from wheels and moving parts
FloatLift should be left in the fully up position
Connecting a powerpack to a FloatLift in a different lifting position then when disconnected
will cause changes to fluid level, and possible overflowing of fluid.