PART NO. 690809 REV: A 34
Lift Operation 5 minutes
Up and down buttons on RC Unit are operational
Up and down on remotes is operational
Lifting time less than 2 minutes (3 minutes for FL36 and FL40)
Power unit A and B functioning (turn off A and B individually with circuit breakers)
If included, Emergency down button on front of box operates lift down
Run lift completely down and then back up
Lifts evenly with boat
Lifts evenly without boat
Comments____________________________________
Fluid
Fluid level is 1-2 inches from top of reservoir
Fluid is a pink/red color
No visual particulate matter in fluid
Comments____________________________________
Powerpack 5 minutes
Check for evidence of fluid leaks
Ensure drain holes are not clogged
Remove any items not related to boat lift from powerpack
Clean inside and outside of box, including solar panels with wet rag
Spray battery terminals, hydraulic fittings with anti-corrosion spray such as T-9 or WD-40
Comments____________________________________
Lift Structure
Floats 10 minutes
All floats appear to be equally buoyant
With boat
Without boat
Comments____________________________________