EasyManua.ls Logo

Superior DRT2040 - User Manual

Superior DRT2040
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation and Operation Instructions
Superior™ DRT2000 and DRC2000
Direct-Vent Gas Fireplaces
P/N 900004-00 Rev. G 04/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900004-02.
PFS
®
USC
Models
DRT2033xxx *
DRC2033xxx *
DRT2035xxx *
DRC2035xxx *
DRT2040xxx *
DRC2040xxx *
DRT2045xxx *
DRC2045xxx *
P900004-00
* “xxx” indicates unique model identifiers. This manual covers all Superior™
DRT2000 and DRC2000 models.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
L’écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
Report No. F13-094

Other manuals for Superior DRT2040

Questions and Answers

  • D
    Dale LawsonSep 1, 2025
    Why does my Superior DRT2040 main burner come on but then goes out?
    • A
      Ashley HillSep 1, 2025
      If the main burner of your Superior Indoor Fireplace comes on but then goes out, check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Inspect the control compartment for any loose wiring to the valve or ignition module, if necessary, call a service technician. Also, if the pilot flame is not engulfing the sensor or the vent system is obstructed, call a service technician.
  • J
    jmoonAug 31, 2025
    What causes soot on the logs and glass of my Superior Indoor Fireplace?
    • A
      Ashley HullAug 31, 2025
      Soot on the logs and glass of your Superior Indoor Fireplace can result from several factors. Ensure the logs are properly positioned. A white film may develop on the glass during initial operation of the fireplace. Clean the glass after each use until the film disappears. Check and adjust the vent restrictor setting and air shutter opening according to the instructions in this manual.
  • D
    Denise DouglasAug 29, 2025
    What to do if nothing happens when Superior DRT2040 Indoor Fireplace is turned ON/OFF?
    • M
      mashleyAug 29, 2025
      If nothing happens when you turn your Superior Indoor Fireplace ON or OFF, first ensure that the wall switch plate is set to REMOTE. Next, check the gas supply and gas shutoff valves to confirm that gas is reaching the fireplace. Finally, check or replace the backup batteries behind the wall plate.
  • L
    Larry WiseAug 27, 2025
    What to do if Superior Indoor Fireplace main burner does not light but the igniter is sparking?
    • D
      Danielle EvansAug 27, 2025
      If the main burner on your Superior Indoor Fireplace doesn't light even though the igniter is sparking, first check the gas supply and shutoff valves to ensure gas is reaching the fireplace. Inspect the control compartment for any loose wiring to the valve or ignition module, if necessary, call a service technician. If there is air in the gas line, purge the gas line of air, if required, call a service technician. Also, check and replace the unit battery backup.
  • U
    underwoodcassandraAug 26, 2025
    What causes frequent pilot/burner outage problem in Superior DRT2040 Indoor Fireplace?
    • T
      Terry MahoneyAug 26, 2025
      Frequent pilot/burner outages in your Superior Indoor Fireplace can be caused by a pilot flame that is too low or too high. Clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple. This will help prevent the pilot/valve safety from dropping out.
  • B
    brownmichelleAug 25, 2025
    What to do if Superior DRT2040 pilot will not stay lit?
    • A
      Andrea SandersAug 25, 2025
      If the pilot light on your Superior Indoor Fireplace won't stay lit after following the lighting instructions, the pilot flame might not be properly impinging on the thermocouple. Ensure the pilot flame makes good contact with the thermocouple. You may need to clean and/or adjust the pilot for maximum flame impingement. Also, check that the connection between the valve and thermocouple is tight and secure.
  • T
    toni23Aug 22, 2025
    Why is my Superior DRT2040 pilot burning but no gas to burner?
    • O
      orodriguezAug 22, 2025
      If the pilot light is on in your Superior Indoor Fireplace, but no gas is reaching the burner, and the valve knob and burner switch are both in the 'ON' position, several issues could be the cause. A defective wall switch or faulty wiring could be the problem; check the connections or try using a jumper wire across the terminals at the wall switch. Also, the thermopile may not be generating enough millivolts; it should read a minimum of 325 millivolts with the optional wall switch OFF. If it reads lower, the thermopile may need replacing. Additionally, a plugged burner orifice could be blocking the gas flow; inspect and clear any blockages. Finally, make sure that only one of the switches is in the ON position.

Summary

General Information

Important Safety Information

Crucial safety warnings and guidelines for appliance use.

Introduction

Overview of the direct-vent gas fireplaces and their features.

Installation

Massachusetts Installation Requirements

Specific installation rules for Massachusetts compliance.

Manufactured Home Installation

Guidelines for installing the appliance in manufactured homes.

Location Selection

Guidance on choosing an appropriate and safe location for the fireplace.

Vent Termination Clearances

Specifies required clearances for vent terminations for safety.

Clearances to Combustibles

Details clearances required from combustible materials for fire safety.

Installation Sequence

Outlines the step-by-step process for installing the fireplace.

Vent System Installation

Comprehensive guide for installing the direct-vent system correctly.

Horizontal Termination Vent System

Specific steps for terminating the vent horizontally through an exterior wall.

Operation

Gas Connection and Operation Verification

Steps for connecting gas, verifying operation, and adjusting flame.

Installing Decorative Components

Instructions for placing logs, volcanic stone, and glowing embers.

Glass Door Installation

Steps for installing and removing the fireplace glass door.

Maintenance

Venting System Inspection

Procedures for checking the vent system for obstructions and damage.

Burner Flame Appearance Inspection

Checking burner and pilot flame for proper appearance and function.

Glass Door Cleaning

Instructions for safely cleaning the fireplace glass door.

Maintenance Schedule

Detailed schedule for required maintenance tasks.

Accessory Components

Forced Air Kits

Information on optional blower kits for enhanced air circulation.

Decorative Media and Liners

Details on glass media, volcanic stone, and firebox liners.

Termination Guard Kits

Components to cover vent terminations for aesthetic and safety reasons.

Troubleshooting

Millivolt System Troubleshooting

Common issues and solutions for millivolt ignition systems.

Electronic System Troubleshooting

Common issues and solutions for electronic ignition systems.

Superior DRT2040 Specifications

General IconGeneral
BrandSuperior
ModelDRT2040
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals