Super C9Z790-CG/-CGW User's Manual
92
GT Voltage Mode
This feature controls the voltage mode in the GT domain. The options are Adaptive
and Override.
*If the feature of GT Voltage Mode is set to Adaptive, the following feature will
become available for conguration:
GT Extra Turbo Voltage
Enter a value for the extra turbo voltage (in mV) that will be applied while GT is operat-
ing in turbo mode. The range is 0-2000. The default is 0.
*If the feature of GT Voltage Mode is set to Override, the following features (SVID
and GT Voltage Override) will become available for conguration:
SVID
Use this feature to enable or disable the SVID. The options are Disabled and Enabled.
GT Voltage Override
Use this feature to specify the override voltage applied to the GT domain (in mV). The
range is 0-2000 and the default is 0.
GT Voltage Oset
Enter a value for the oset voltage (in mV) that will be applied to the GT domain. The
range is -1000 to 1000 and the default is 0.
Oset Prex
Use this feature to set the prex value as a positive (+) or a negative (-). The op-
tions are “+” and “-”.
E-core L2 Conguration
E-Core L2 Voltage Mode
This feature controls the voltage mode in the E-core L2 domain. The options are Adap-
tive and Override.
*If the feature of E-Core L2 Voltage Mode is set to Adaptive, the following feature
will become available for conguration:
E-Core L2 Extra Turbo Voltage
Enter a value for the extra turbo voltage (in mV) that will be applied while E-core L2
is operating in turbo mode. The range is 0-2000. The default is Auto.