Chapter 2: Server Installation
2-7
Figure 2-4. Installing the Outer Rails to the Rack
Installing the Outer Rails onto the Rack
your rack holes. If you have an older rack with round holes, these brackets must be
removed, and you must use screws to secure the rail to the rack.
Outer Rail Installation
1. Align the square pegs on the front end of the rail with the square holes on the
front of the rack (C). Push the rail into the rack until the quick release bracket
snaps into place, securing the rail to the rack. Keep the rail horizontal.
2. Adjust the rail to reach just past the full depth of your rack.
3. Align the square pegs on the rear end of the rail to the holes on the rack (D)
and push the rail into the rack until the quick release bracket snaps into place,
securing the rail to the rack.
4. Repeat the procedure for the other outer rail assembly.
Note:
Stability hazard. The rack stabilizing mechanism must be in place, or the
Failure to stabilize the rack can cause the rack to tip over.
1
C
1
D