2-8
SUPERSERVER 6048R-TXR User's Manual
screw the handles the
outer rails for secure
purpose if necessary
F.
ABLECOM
DATE:2008/08/14
REV:2
SCREW
SCREW
COMPLETE
1
2
Figure 2-5. Installing the Chassis into a Rack
Installing the Chassis into a Rack
1. Extend the outer rails as illustrated above.
2. Align the inner rails of the chassis with the outer rails on the rack.
3. Slide the inner rails into the outer rails, keeping the pressure even on both
sides. When the chassis has been pushed completely into the rack, it should
click into the locked position.
4. Optional screws may be used to secure the front of the chassis to the rack.
Notes: gure is for illustrative purposes only. Always install servers into racks from
the bottom up.
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the oor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.